Análisis de sensibilidad de un circuito magnético para ensayos no destructivos por la técnica de fuga de flujo magnético / (Registro nro. 29668)
[ vista simple ]
000 -CABECERA | |
---|---|
campo de control de longitud fija | nas a22 a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
campo de control | CO-BrAUC |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
campo de control | 20170609151127.0 |
008 - DATOS DE LONGITUD FIJA--INFORMACIÓN GENERAL | |
campo de control de longitud fija | 170606s2016 ck br||ern||| 00| c spa d |
022 ## - NÚMERO INTERNACIONAL NORMALIZADO PARA PUBLICACIONES SERIADAS | |
Fuente | 16928261 |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro catalogador/agencia de origen | CO-BrUAC |
Centro/agencia transcriptor | CO-BrUAC |
Centro/agencia modificador | CO-BrUAC |
082 04 - NÚMERO DE LA CLASIFICACIÓN DECIMAL DEWEY | |
Número de clasificación | 620 |
100 1# - ENTRADA PRINCIPAL--NOMBRE DE PERSONA | |
Nombre de persona | Jaime Saavedra, Cristian Fabian. |
9 (RLIN) | 2625 |
Término indicativo de función/relación | autor |
245 10 - MENCIÓN DE TÍTULO | |
Título | Análisis de sensibilidad de un circuito magnético para ensayos no destructivos por la técnica de fuga de flujo magnético / |
Mención de responsabilidad, etc. | Cristian Fabian Jaime Saavedra. |
Medio | Artículo de Revista. |
246 ## - FORMA VARIANTE DE TÍTULO | |
Título propio/Titulo breve | Sensitivity Analysis of a Magnetic Circuit for Non-Destructive Testing by the Magnetic Flux Leakage Technique / |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | Páginas 22-30 : |
Otras características físicas | ilustraciones |
504 ## - NOTA DE BIBLIOGRAFÍA, ETC. | |
Nota de bibliografía, etc. | Incluye referencias bibliográficas. |
520 ## - SUMARIO, ETC. | |
Sumario, etc. | RESUMEN:<br/>El monitoreo de integridad estructural en la industria petrolera es una tarea muy importante para prevenir desastres tanto ambientales como económicos. Este artículo presenta la optimización de la geometría del circuito magnético para la detección de fallas en oleoductos por la técnica de fuga de flujo magnético. El objetivo principal es realizar un análisis de los parámetros geométricos del circuito para encontrar la configuración que incremente el desempeño del sistema para la detección de fallas. El análisis de la sensibilidad de los parámetros del circuito se basa en una evaluación numérica del desempeño del sistema usando el análisis por el método de los elementos finitos. El software comercial utilizado para este análisis fue COMSOL Multiphysics®. Los resultados obtenidos en esta investigación sirven para identificar la configuración geométrica adecuada para la mejora del desempeño del sistema, con respecto a otras configuraciones, para la detección de la misma falla. También haciendo uso del modelo matemático del fenómeno, se pretende comparar los resultados obtenidos por el modelo matemático y el modelo por elementos finitos. Los descubrimientos en esta investigación pueden ser usados como guías para el diseño de circuitos magnéticos para ensayos no destructivos por la técnica de fuga de flujo magnético.<br/><br/> |
520 ## - SUMARIO, ETC. | |
Sumario, etc. | ABSTRACT:<br/>Monitoring the integrity of structures in the oil and gas industry is a mandatory task to prevent both<br/>natural disasters and economical losses. This paper presents the optimization of the geometry of a<br/>magnetic circuit for the detection of defects in pipelines by the magnetic flux leakage method. The main<br/>goal is to perform a sensitivity analysis on the geometrical parameters of the circuit to find configurations<br/>that improve the performance of the defect searching tool. The sensitivity analysis of the design<br/>parameters of the magnetic circuit is based on numerical evaluations of the performance of the tool using<br/>the finite element method. The commercial finite elements software utilized for this analysis is COMSOL<br/>Multiphysics®. The results obtained in this investigation serve to identify the geometrical configurations<br/>that provide better performance, with respect to other configurations, for the detection of the same defect.<br/>Also, by using the analytical model of the magnetic flux leakage, the results obtained by means of the<br/>analytical model can be compared to the results from the finite elements model. The findings of this<br/>investigation can be utilized as guidelines for the design of magnetic circuits for non-destructive testing<br/>using the magnetic flux leakage technique.<br/> |
650 14 - PUNTO DE ACCESO ADICIONAL DE MATERIA--TÉRMINO DE MATERIA | |
Término de materia o nombre geográfico como elemento de entrada | Fuga de flujo magnético |
Subdivisión general | Análisis de Sensibilidad |
Subdivisión de forma | Artículo de Revista. |
9 (RLIN) | 2555 |
658 ## - TÉRMINO DE INDIZACIÓN--OBJETIVO CURRICULAR | |
Objetivo curricular principal | |
700 1# - PUNTO DE ACCESO ADICIONAL--NOMBRE DE PERSONA | |
Nombre de persona | Roa Prada, Sebastian |
Término indicativo de función/relación | autor |
9 (RLIN) | 2626 |
773 0# - ENLACE AL DOCUMENTO FUENTE/ENTRADA DE REGISTRO ANFITRIÓN | |
Número bibliográfico anfitrión | 18536 |
Número de ítem anfitrión | 52515 |
Encabezamiento principal | Universidad Autónoma del Caribe: |
Lugar, editor y fecha de publicación | Barranquilla, Colombia. : Editorial Uniautónoma, 2004. |
Otro identificador del documento | 10405001400021080364 |
Título | Prospectiva : |
Número de control del registro | (CO-BrAUC)000012445 |
Número Internacional Normalizado para Publicaciones Seriadas | 16928261 (pasta blanda) |
856 41 - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Nombre del host | |
Texto de enlace | Artículo en texto completo |
Identificador Uniforme del Recurso | <a href="http://dx.doi.org/10.15665/rp.v14i2.678 ">http://dx.doi.org/10.15665/rp.v14i2.678 </a> |
942 ## - ELEMENTOS DE PUNTO DE ACCESO ADICIONAL (KOHA) | |
Fuente del sistema de clasificación o colocación | Sistema de Clasificación Decimal Dewey |
Tipo de ítem Koha | Artículo |
Parte de la signatura que corresponde a la clasificación (Parte de la clasificación) | 620 |
No hay ítems disponibles.